Gas Valve, NG/LP, Standing Pilot, 24VAC, 3.5 in wc, Combination

Introducing the Gas Valve, a versatile and high-performing solution for managing natural gas and liquid propane systems. With its combination design and standing pilot ignition, this gas valve offers reliable operation and precise control. It is suitable for a wide range of applications, from residential heating systems to commercial boilers.

Technical Specifications

  • Inlet Size: 1/2 in
  • Outlet Size: 3/4 in
  • Pilot Port Connection Size: 1/4 in
  • Port Connection Size: 3/4 in
  • BtuH Capacity: 240,000 BtuH
  • Coil Volts: 24 V
  • Gas Type: NG/LP
  • Ignition Type: Standing Pilot
  • Reducer Bushing Kit: 3/4 x 1/2 in
  • Valve Type: Combination
  • Amps AC: 0.2 A
  • Ambient Temp. Range: -40 Degrees F to 175 Degrees F
  • Item: Gas Valve
  • LP Conversion Kit: Yes
  • Pressure Setting Range: 3.5 in wc
  • Flow Direction: Straight-Thru
  • Includes: 3/4 x 1/2 in Reducer Bushing, Outlet Pressure Tap, Regulator Cover Plate to Convert to LP
  • Max. Inlet Pressure: 1/2 psi
  • Standards: NEMA, RoHS compliant
  • Side Taps: No
  • Inlet Pressure Tap: No
  • Manufacturer Series: 700
  • Reducer Bushings Included: 3/4 x 1/2 in
  • Port Connection Type: NPT
  • Valve Design: Single
  • Port Connection Gender: Female
  • Electrical Connections: Screw/Spade Terminal
  • Pilot Type: Standing Pilot
  • Includes Thermostat: Mechanical Thermostat Not Included
  • Sensing Type: Flame Sensor
  • Voltage: 24V AC
  • Includes Conversion Kit: Conversion Kit Included
  • Current: 0.2 A
  • Includes On/Off Switch: On/Pilot/Off Switch Included
  • Opening Characteristic: Fast Opening
  • Includes Pilot Generator Kit: Pilot Generator Kit Not Included
  • Heating Capacity - Maximum: 240,000 BtuH
  • Operating Temperature - Minimum: -40 Degrees F
  • Includes Pressure Regulator: Pressure Regulator Included
  • For Media: Liquid Propane, Natural Gas
  • Operating Temperature - Maximum: 175 Degrees F
  • Installation Orientation: Versatile
  • Includes Side Taps: Side Taps Not Included
  • Pilot Port Connection Type: Compression
  • Includes Pressure Tap: Pressure Tap Outlet Included

Performance Benefits

With its fast opening characteristic and precise control, this gas valve ensures optimal heating performance. Its compatibility with both natural gas and liquid propane makes it suitable for a variety of applications. The included conversion kit simplifies the process of switching between fuel types, saving time and effort. Additionally, the on/off switch provides convenient control over the system's operation.

Engineering Features

  • The combination design of this gas valve allows for versatile installation and integration into heating systems.
  • The durable construction and high-quality materials ensure long-lasting performance and reliability.
  • The screw/spade terminal electrical connections provide secure and efficient electrical connections.
  • The standing pilot ignition offers reliable and consistent ignition performance.
  • The pressure regulator, included in the package, ensures precise control over gas pressure.

Product Applications

This gas valve is commonly used in residential and commercial heating systems, such as furnaces, boilers, and water heaters. It is compatible with both natural gas and liquid propane, making it suitable for a wide range of applications in various industries, including HVAC, construction, and manufacturing.

Installation & Integration

  • This gas valve is designed for compatibility with standard NPT port connections and female port connection gender.
  • It can be easily installed in straight-thru flow direction scenarios.
  • Common installation scenarios include integration into heating systems, such as furnaces and boilers.

Troubleshooting & Maintenance

Common technical scenarios that may require troubleshooting include issues with the standing pilot ignition and pressure regulation. Regular preventive maintenance, including inspection and cleaning, is recommended to ensure optimal performance. If replacement is necessary, it is important to select a gas valve with compatible specifications to maintain system compatibility.

Shipping This item ships to
Delivery Estimated between and . Will usually ship within 1 business day.

Description

Gas Valve, NG/LP, Standing Pilot, 24VAC, 3.5 in wc, Combination

Introducing the Gas Valve, a versatile and high-performing solution for managing natural gas and liquid propane systems. With its combination design and standing pilot ignition, this gas valve offers reliable operation and precise control. It is suitable for a wide range of applications, from residential heating systems to commercial boilers.

Technical Specifications

  • Inlet Size: 1/2 in
  • Outlet Size: 3/4 in
  • Pilot Port Connection Size: 1/4 in
  • Port Connection Size: 3/4 in
  • BtuH Capacity: 240,000 BtuH
  • Coil Volts: 24 V
  • Gas Type: NG/LP
  • Ignition Type: Standing Pilot
  • Reducer Bushing Kit: 3/4 x 1/2 in
  • Valve Type: Combination
  • Amps AC: 0.2 A
  • Ambient Temp. Range: -40 Degrees F to 175 Degrees F
  • Item: Gas Valve
  • LP Conversion Kit: Yes
  • Pressure Setting Range: 3.5 in wc
  • Flow Direction: Straight-Thru
  • Includes: 3/4 x 1/2 in Reducer Bushing, Outlet Pressure Tap, Regulator Cover Plate to Convert to LP
  • Max. Inlet Pressure: 1/2 psi
  • Standards: NEMA, RoHS compliant
  • Side Taps: No
  • Inlet Pressure Tap: No
  • Manufacturer Series: 700
  • Reducer Bushings Included: 3/4 x 1/2 in
  • Port Connection Type: NPT
  • Valve Design: Single
  • Port Connection Gender: Female
  • Electrical Connections: Screw/Spade Terminal
  • Pilot Type: Standing Pilot
  • Includes Thermostat: Mechanical Thermostat Not Included
  • Sensing Type: Flame Sensor
  • Voltage: 24V AC
  • Includes Conversion Kit: Conversion Kit Included
  • Current: 0.2 A
  • Includes On/Off Switch: On/Pilot/Off Switch Included
  • Opening Characteristic: Fast Opening
  • Includes Pilot Generator Kit: Pilot Generator Kit Not Included
  • Heating Capacity - Maximum: 240,000 BtuH
  • Operating Temperature - Minimum: -40 Degrees F
  • Includes Pressure Regulator: Pressure Regulator Included
  • For Media: Liquid Propane, Natural Gas
  • Operating Temperature - Maximum: 175 Degrees F
  • Installation Orientation: Versatile
  • Includes Side Taps: Side Taps Not Included
  • Pilot Port Connection Type: Compression
  • Includes Pressure Tap: Pressure Tap Outlet Included

Performance Benefits

With its fast opening characteristic and precise control, this gas valve ensures optimal heating performance. Its compatibility with both natural gas and liquid propane makes it suitable for a variety of applications. The included conversion kit simplifies the process of switching between fuel types, saving time and effort. Additionally, the on/off switch provides convenient control over the system's operation.

Engineering Features

  • The combination design of this gas valve allows for versatile installation and integration into heating systems.
  • The durable construction and high-quality materials ensure long-lasting performance and reliability.
  • The screw/spade terminal electrical connections provide secure and efficient electrical connections.
  • The standing pilot ignition offers reliable and consistent ignition performance.
  • The pressure regulator, included in the package, ensures precise control over gas pressure.

Product Applications

This gas valve is commonly used in residential and commercial heating systems, such as furnaces, boilers, and water heaters. It is compatible with both natural gas and liquid propane, making it suitable for a wide range of applications in various industries, including HVAC, construction, and manufacturing.

Installation & Integration

  • This gas valve is designed for compatibility with standard NPT port connections and female port connection gender.
  • It can be easily installed in straight-thru flow direction scenarios.
  • Common installation scenarios include integration into heating systems, such as furnaces and boilers.

Troubleshooting & Maintenance

Common technical scenarios that may require troubleshooting include issues with the standing pilot ignition and pressure regulation. Regular preventive maintenance, including inspection and cleaning, is recommended to ensure optimal performance. If replacement is necessary, it is important to select a gas valve with compatible specifications to maintain system compatibility.

Shipping

Shipping This item ships to
Delivery Estimated between and . Will usually ship within 1 business day.

No reviews yet. Be the first to review this product!

Frequently Asked Questions

What does the Robertshaw 700-400 Gas Valve NG/LP Standing Pilot do?
The Robertshaw 700-400 Gas Valve NG/LP Standing Pilot controls the flow of gas to the burner and pilot in your Robertshaw fireplace. It regulates gas pressure and responds to signals from the thermocouple, thermopile, or electronic control module to operate safely.
What are the signs I need to replace my gas valve?
Signs include the fireplace not lighting at all, gas smell without ignition, the pilot not staying lit despite a good thermocouple, or the valve making clicking sounds without opening. A faulty gas valve should be replaced promptly for safety.
Should I install a gas valve myself?
Gas valve replacement involves working with gas supply lines and should be performed by a qualified, licensed gas technician. Improper installation can lead to gas leaks and serious safety hazards.
Is the Robertshaw 700-400 Gas Valve NG/LP Standing Pilot compatible with my fireplace?
This gas valve is made for specific Robertshaw fireplace models. Gas valves are not interchangeable between models, so verify the exact part number against your fireplace's specifications before ordering.
3 visitors right now
3 visitors have this item in their cart right now
3 people have bought this item
3 % of people buy 2 or more

Recently viewed products

3 people are currently viewing this item
3 visitors have this item in their cart right now 🛒
Only 3 left! .. people are viewing this, and 3 recently purchased it
3 People have recently bought this