Unmatched Temperature Control and Protection
Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

Free Shipping On Orders Over $99

White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary

SKU: 16A60-9

Great reasons to buy from us:

  • Image of FREE Shipping on Orders over $199

    Free Shipping

    FREE Shipping on Orders over $199
  • Image of 110% Price Match Guarantee

    We will beat any price

    110% Price Match Guarantee
  • Image of In Stock Orders Ship in 24-48 hours

    Fast Shipping

    In Stock Orders Ship in 24-48 hours
  • Image of Up To 20% Off! Don't miss out on this limited time offer!

    Huge Discounts

    Up To 20% Off! Don't miss out on this limited time offer!

White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary - Ensure Optimal Temperature Control

Introducing the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary - a technologically advanced solution designed to provide reliable freeze protection control for indoor single-stage systems. With its impressive range of features and superior performance, this control unit guarantees optimal temperature regulation in a variety of environments.

Key Benefits - Unmatched Temperature Control and Protection

The White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary offers a range of key benefits that set it apart from competitors. Its hydraulic capillary bulb sensor ensures accurate temperature readings, allowing for precise control and preventing freezing conditions. With a wide operating temperature range of -29 Degrees to 140 Degrees F, this control unit can handle extreme temperatures and maintain the desired conditions consistently. The NEMA 3 enclosure rating ensures durability and protection against harsh environmental conditions, making it suitable for both indoor and outdoor applications. Additionally, the manual reset differential type provides extra safety, allowing for immediate action in case of temperature anomalies.

Unique Features - Unparalleled Performance

One of the standout features of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary is its close on rise switch action, enabling precise temperature control and preventing freezing or overheating. The remote sensor location feature allows for flexible installation options, ensuring accurate readings even in challenging environments. Furthermore, the 1C stage configuration and 120V AC, 240V AC contact rating make this control unit suitable for a wide range of heating systems, providing compatibility and versatility.

Choose the White-Rodgers 16A60-9 Freeze Protection Control for Unrivaled Performance

When it comes to temperature control and freeze protection, the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary stands above the competition. Its advanced features, such as the hydraulic capillary bulb sensor and manual reset differential type, ensure precise and reliable temperature regulation. With its durable NEMA 3 enclosure rating and wide operating temperature range, this control unit guarantees optimal performance in any environment. Don't compromise on temperature control - choose the White-Rodgers 16A60-9 Freeze Protection Control for superior protection and peace of mind.

Take control of your temperature regulation today and experience the unmatched performance of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary. Contact us now to learn more or make a purchase.

💡 Features

  • Hydraulic capillary bulb sensor for accurate temperature readings
  • Close on rise switch action for precise control
  • Wide operating temperature range of -29 Degrees to 140 Degrees F
  • NEMA 3 enclosure rating for durability and protection
  • Manual reset differential type for enhanced safety
  • 1C stage configuration for compatibility with various heating systems
  • 120V AC, 240V AC contact rating for versatility
  • Remote sensor location for flexible installation

📏 Specifications

  • Item: Freeze Protection Control, w/Capillary
  • Standards: cULus
  • Changeover Type: Manual
  • Thermostat Type: Freeze Protection Indoor Single-Stage Controls
  • Operating Temperature Range: -29 Degrees to 140 Degrees F
  • Enclosure NEMA Rating: NEMA 3
  • Switch Action: Close on Rise
  • Full Load Amps @ 120V AC: 7.4 A
  • Sensor Type: Hydraulic Capillary Bulb (Copper)
  • Differential Type: Manual Reset
  • Stages: 1C
  • Minimum Control Temperature: -30 Degrees F
  • Maximum Control Temperature: 50 Degrees F
  • Contact Rating: 120V AC, 240V AC
  • Temperature Differential: Manual Reset
  • Sensor Location: Remote
  • Maximum Operating Temperature: 140 Degrees F

Frequently Asked Questions

Q: What is the operating temperature range of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary?
A: The operating temperature range is -29 Degrees to 140 Degrees F, allowing for reliable performance in extreme conditions. Q: Does this control unit have a manual reset differential?
A: Yes, the White-Rodgers 16A60-9 Freeze Protection Control features a manual reset differential for added safety and immediate response to temperature anomalies. Q: What is the enclosure rating of this control unit?
A: The White-Rodgers 16A60-9 has an NEMA 3 enclosure rating, providing durability and protection against harsh environmental conditions. Q: Can this control unit be used for both indoor and outdoor applications?
A: Absolutely! The NEMA 3 enclosure rating ensures that the control unit is suitable for both indoor and outdoor installations, offering versatility and reliability. Q: What is the contact rating of the White-Rodgers 16A60-9 Freeze Protection Control?
A: This control unit has a contact rating of 120V AC, 240V AC, making it compatible with a wide range of heating systems.
Shipping This item ships to
Delivery Estimated between and . Will usually ship within 1 business day.

Description

White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary - Ensure Optimal Temperature Control

Introducing the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary - a technologically advanced solution designed to provide reliable freeze protection control for indoor single-stage systems. With its impressive range of features and superior performance, this control unit guarantees optimal temperature regulation in a variety of environments.

Key Benefits - Unmatched Temperature Control and Protection

The White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary offers a range of key benefits that set it apart from competitors. Its hydraulic capillary bulb sensor ensures accurate temperature readings, allowing for precise control and preventing freezing conditions. With a wide operating temperature range of -29 Degrees to 140 Degrees F, this control unit can handle extreme temperatures and maintain the desired conditions consistently. The NEMA 3 enclosure rating ensures durability and protection against harsh environmental conditions, making it suitable for both indoor and outdoor applications. Additionally, the manual reset differential type provides extra safety, allowing for immediate action in case of temperature anomalies.

Unique Features - Unparalleled Performance

One of the standout features of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary is its close on rise switch action, enabling precise temperature control and preventing freezing or overheating. The remote sensor location feature allows for flexible installation options, ensuring accurate readings even in challenging environments. Furthermore, the 1C stage configuration and 120V AC, 240V AC contact rating make this control unit suitable for a wide range of heating systems, providing compatibility and versatility.

Choose the White-Rodgers 16A60-9 Freeze Protection Control for Unrivaled Performance

When it comes to temperature control and freeze protection, the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary stands above the competition. Its advanced features, such as the hydraulic capillary bulb sensor and manual reset differential type, ensure precise and reliable temperature regulation. With its durable NEMA 3 enclosure rating and wide operating temperature range, this control unit guarantees optimal performance in any environment. Don't compromise on temperature control - choose the White-Rodgers 16A60-9 Freeze Protection Control for superior protection and peace of mind.

Take control of your temperature regulation today and experience the unmatched performance of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary. Contact us now to learn more or make a purchase.

💡 Features

  • Hydraulic capillary bulb sensor for accurate temperature readings
  • Close on rise switch action for precise control
  • Wide operating temperature range of -29 Degrees to 140 Degrees F
  • NEMA 3 enclosure rating for durability and protection
  • Manual reset differential type for enhanced safety
  • 1C stage configuration for compatibility with various heating systems
  • 120V AC, 240V AC contact rating for versatility
  • Remote sensor location for flexible installation

📏 Specifications

  • Item: Freeze Protection Control, w/Capillary
  • Standards: cULus
  • Changeover Type: Manual
  • Thermostat Type: Freeze Protection Indoor Single-Stage Controls
  • Operating Temperature Range: -29 Degrees to 140 Degrees F
  • Enclosure NEMA Rating: NEMA 3
  • Switch Action: Close on Rise
  • Full Load Amps @ 120V AC: 7.4 A
  • Sensor Type: Hydraulic Capillary Bulb (Copper)
  • Differential Type: Manual Reset
  • Stages: 1C
  • Minimum Control Temperature: -30 Degrees F
  • Maximum Control Temperature: 50 Degrees F
  • Contact Rating: 120V AC, 240V AC
  • Temperature Differential: Manual Reset
  • Sensor Location: Remote
  • Maximum Operating Temperature: 140 Degrees F

Frequently Asked Questions

Q: What is the operating temperature range of the White-Rodgers 16A60-9 Freeze Protection Control, w/Capillary?
A: The operating temperature range is -29 Degrees to 140 Degrees F, allowing for reliable performance in extreme conditions. Q: Does this control unit have a manual reset differential?
A: Yes, the White-Rodgers 16A60-9 Freeze Protection Control features a manual reset differential for added safety and immediate response to temperature anomalies. Q: What is the enclosure rating of this control unit?
A: The White-Rodgers 16A60-9 has an NEMA 3 enclosure rating, providing durability and protection against harsh environmental conditions. Q: Can this control unit be used for both indoor and outdoor applications?
A: Absolutely! The NEMA 3 enclosure rating ensures that the control unit is suitable for both indoor and outdoor installations, offering versatility and reliability. Q: What is the contact rating of the White-Rodgers 16A60-9 Freeze Protection Control?
A: This control unit has a contact rating of 120V AC, 240V AC, making it compatible with a wide range of heating systems.

Shipping

Shipping This item ships to
Delivery Estimated between and . Will usually ship within 1 business day.
3 visitors right now
3 visitors have this item in their cart right now
3 people have bought this item
3 % of people buy 2 or more

Recently viewed products