Gas Orifice Size Chart and Calculator
A gas orifice is the small brass fitting with a precisely drilled hole that meters gas into a burner. The size of that hole and the gas pressure behind it set the burner's input in BTU per hour, which is why natural gas and propane (LP) appliances use different orifices. The charts below give the approximate input for every number drill size from #1 to #80 and for common metric sizes, and the orifice calculator on this page runs the same math for any pressure, heating value or altitude.
Use these numbers as a reference, not as a conversion recipe. Your appliance's rating plate and the maker's conversion kit are the authority, and orifice changes and gas conversions are work for a licensed gas installer. See Safety below.
How to Read the Orifice Size Chart
- Find the size stamped on the orifice. Most burner orifices are stamped with a number drill size, such as #34 (Kozy Heat writes it "#34 (DMS)"). Some makers stamp a metric size in millimeters instead; Empire, for example, uses orifices marked 1.45, 2.25 and 2.40. The higher the drill number, the smaller the hole: a #80 is 0.0135 in. and a #1 is 0.228 in.
- Read across to your gas and pressure. Each figure is the BTU per hour through one orifice at sea level, at the manifold pressure in the column heading. Manifold pressure is measured at the gas valve's outlet pressure tap with a manometer, and the right value is on the rating plate or in the manual.
- Add up every orifice on the burner. A burner with front and rear orifices fires at their total. Example: an Empire DVCT36CBP9 converted to natural gas uses a #48 front orifice and a 2.40 mm rear orifice. The chart gives 16,400 + 25,300 = 41,700 BTU/hr, and Empire rates it at 40,000 BTU/hr.
- Pressure matters less than you might think. Flow rises with the square root of pressure, so raising a natural gas manifold from 3.5 to 4.0 in. w.c. adds only about 7%.
- Treat every figure as plus or minus 5%. Real orifices vary with the shape of the hole and the burner design. Against seven maker-rated fireplace inputs, these charts land within about 4%.
- Pilot orifices are a different animal. Pilot injectors are tiny and are often marked with the maker's own code rather than a drill number (Kozy Heat marks one natural gas pilot injector "#.023NG", a decimal size). Replace a pilot injector by part number, not from this chart.
Natural Gas Orifice Size Chart (3.5 in. w.c.)
Natural gas at 3.5 in. w.c. manifold pressure, a common setting for gas fireplaces, inserts and stoves (Empire's conversion instructions, for example, set natural gas to about 3.5 in. w.c. at the valve outlet). Basis: 1,000 BTU per cubic foot, specific gravity 0.60, discharge coefficient 0.90, sea level. Values under 10,000 are rounded to the nearest 10 BTU/hr, larger values to the nearest 100.
| Drill size | Diameter (in.) | Diameter (mm) | Natural gas BTU/hr at 3.5 in. w.c. |
|---|---|---|---|
| #1 | 0.228 | 5.79 | 147,200 |
| #2 | 0.221 | 5.61 | 138,300 |
| #3 | 0.213 | 5.41 | 128,500 |
| #4 | 0.209 | 5.31 | 123,700 |
| #5 | 0.2055 | 5.22 | 119,600 |
| #6 | 0.204 | 5.18 | 117,800 |
| #7 | 0.201 | 5.11 | 114,400 |
| #8 | 0.199 | 5.05 | 112,100 |
| #9 | 0.196 | 4.98 | 108,800 |
| #10 | 0.1935 | 4.91 | 106,000 |
| #11 | 0.191 | 4.85 | 103,300 |
| #12 | 0.189 | 4.80 | 101,100 |
| #13 | 0.185 | 4.70 | 96,900 |
| #14 | 0.182 | 4.62 | 93,800 |
| #15 | 0.180 | 4.57 | 91,700 |
| #16 | 0.177 | 4.50 | 88,700 |
| #17 | 0.173 | 4.39 | 84,700 |
| #18 | 0.1695 | 4.31 | 81,300 |
| #19 | 0.166 | 4.22 | 78,000 |
| #20 | 0.161 | 4.09 | 73,400 |
| #21 | 0.159 | 4.04 | 71,600 |
| #22 | 0.157 | 3.99 | 69,800 |
| #23 | 0.154 | 3.91 | 67,200 |
| #24 | 0.152 | 3.86 | 65,400 |
| #25 | 0.1495 | 3.80 | 63,300 |
| #26 | 0.147 | 3.73 | 61,200 |
| #27 | 0.144 | 3.66 | 58,700 |
| #28 | 0.1405 | 3.57 | 55,900 |
| #29 | 0.136 | 3.45 | 52,400 |
| #30 | 0.1285 | 3.26 | 46,800 |
| #31 | 0.120 | 3.05 | 40,800 |
| #32 | 0.116 | 2.95 | 38,100 |
| #33 | 0.113 | 2.87 | 36,200 |
| #34 | 0.111 | 2.82 | 34,900 |
| #35 | 0.110 | 2.79 | 34,300 |
| #36 | 0.1065 | 2.71 | 32,100 |
| #37 | 0.104 | 2.64 | 30,600 |
| #38 | 0.1015 | 2.58 | 29,200 |
| #39 | 0.0995 | 2.53 | 28,000 |
| #40 | 0.098 | 2.49 | 27,200 |
| #41 | 0.096 | 2.44 | 26,100 |
| #42 | 0.0935 | 2.37 | 24,800 |
| #43 | 0.089 | 2.26 | 22,400 |
| #44 | 0.086 | 2.18 | 20,900 |
| #45 | 0.082 | 2.08 | 19,000 |
| #46 | 0.081 | 2.06 | 18,600 |
| #47 | 0.0785 | 1.99 | 17,400 |
| #48 | 0.076 | 1.93 | 16,400 |
| #49 | 0.073 | 1.85 | 15,100 |
| #50 | 0.070 | 1.78 | 13,900 |
| #51 | 0.067 | 1.70 | 12,700 |
| #52 | 0.0635 | 1.61 | 11,400 |
| #53 | 0.0595 | 1.51 | 10,000 |
| #54 | 0.055 | 1.40 | 8,570 |
| #55 | 0.052 | 1.32 | 7,660 |
| #56 | 0.0465 | 1.18 | 6,120 |
| #57 | 0.043 | 1.09 | 5,240 |
| #58 | 0.042 | 1.07 | 4,990 |
| #59 | 0.041 | 1.04 | 4,760 |
| #60 | 0.040 | 1.02 | 4,530 |
| #61 | 0.039 | 0.99 | 4,310 |
| #62 | 0.038 | 0.97 | 4,090 |
| #63 | 0.037 | 0.94 | 3,880 |
| #64 | 0.036 | 0.91 | 3,670 |
| #65 | 0.035 | 0.89 | 3,470 |
| #66 | 0.033 | 0.84 | 3,080 |
| #67 | 0.032 | 0.81 | 2,900 |
| #68 | 0.031 | 0.79 | 2,720 |
| #69 | 0.0292 | 0.74 | 2,410 |
| #70 | 0.028 | 0.71 | 2,220 |
| #71 | 0.026 | 0.66 | 1,910 |
| #72 | 0.025 | 0.64 | 1,770 |
| #73 | 0.024 | 0.61 | 1,630 |
| #74 | 0.0225 | 0.57 | 1,430 |
| #75 | 0.021 | 0.53 | 1,250 |
| #76 | 0.020 | 0.51 | 1,130 |
| #77 | 0.018 | 0.46 | 920 |
| #78 | 0.016 | 0.41 | 720 |
| #79 | 0.0145 | 0.37 | 600 |
| #80 | 0.0135 | 0.34 | 520 |
Propane (LP) Orifice Size Chart (10 and 11 in. w.c.)
Propane at two manifold pressures. Many gas fireplaces, inserts and stoves set propane to about 10.0 in. w.c. at the valve outlet (Empire's propane conversion instructions are one example), while the National Fuel Gas Code's propane orifice table is based on 11.0 in. w.c. Use the column that matches your rating plate or manual. Basis: 2,500 BTU per cubic foot, specific gravity 1.52, discharge coefficient 0.90, sea level.
| Drill size | Diameter (in.) | Diameter (mm) | Propane BTU/hr at 10.0 in. w.c. | Propane BTU/hr at 11.0 in. w.c. |
|---|---|---|---|---|
| #1 | 0.228 | 5.79 | 390,800 | 409,900 |
| #2 | 0.221 | 5.61 | 367,200 | 385,100 |
| #3 | 0.213 | 5.41 | 341,100 | 357,700 |
| #4 | 0.209 | 5.31 | 328,400 | 344,400 |
| #5 | 0.2055 | 5.22 | 317,500 | 333,000 |
| #6 | 0.204 | 5.18 | 312,800 | 328,100 |
| #7 | 0.201 | 5.11 | 303,700 | 318,500 |
| #8 | 0.199 | 5.05 | 297,700 | 312,200 |
| #9 | 0.196 | 4.98 | 288,800 | 302,900 |
| #10 | 0.1935 | 4.91 | 281,500 | 295,200 |
| #11 | 0.191 | 4.85 | 274,200 | 287,600 |
| #12 | 0.189 | 4.80 | 268,500 | 281,600 |
| #13 | 0.185 | 4.70 | 257,300 | 269,800 |
| #14 | 0.182 | 4.62 | 249,000 | 261,200 |
| #15 | 0.180 | 4.57 | 243,600 | 255,500 |
| #16 | 0.177 | 4.50 | 235,500 | 247,000 |
| #17 | 0.173 | 4.39 | 225,000 | 236,000 |
| #18 | 0.1695 | 4.31 | 216,000 | 226,500 |
| #19 | 0.166 | 4.22 | 207,100 | 217,300 |
| #20 | 0.161 | 4.09 | 194,900 | 204,400 |
| #21 | 0.159 | 4.04 | 190,000 | 199,300 |
| #22 | 0.157 | 3.99 | 185,300 | 194,300 |
| #23 | 0.154 | 3.91 | 178,300 | 187,000 |
| #24 | 0.152 | 3.86 | 173,700 | 182,200 |
| #25 | 0.1495 | 3.80 | 168,000 | 176,200 |
| #26 | 0.147 | 3.73 | 162,400 | 170,400 |
| #27 | 0.144 | 3.66 | 155,900 | 163,500 |
| #28 | 0.1405 | 3.57 | 148,400 | 155,600 |
| #29 | 0.136 | 3.45 | 139,000 | 145,800 |
| #30 | 0.1285 | 3.26 | 124,100 | 130,200 |
| #31 | 0.120 | 3.05 | 108,300 | 113,500 |
| #32 | 0.116 | 2.95 | 101,200 | 106,100 |
| #33 | 0.113 | 2.87 | 96,000 | 100,700 |
| #34 | 0.111 | 2.82 | 92,600 | 97,100 |
| #35 | 0.110 | 2.79 | 91,000 | 95,400 |
| #36 | 0.1065 | 2.71 | 85,300 | 89,400 |
| #37 | 0.104 | 2.64 | 81,300 | 85,300 |
| #38 | 0.1015 | 2.58 | 77,400 | 81,200 |
| #39 | 0.0995 | 2.53 | 74,400 | 78,100 |
| #40 | 0.098 | 2.49 | 72,200 | 75,700 |
| #41 | 0.096 | 2.44 | 69,300 | 72,700 |
| #42 | 0.0935 | 2.37 | 65,700 | 68,900 |
| #43 | 0.089 | 2.26 | 59,500 | 62,500 |
| #44 | 0.086 | 2.18 | 55,600 | 58,300 |
| #45 | 0.082 | 2.08 | 50,500 | 53,000 |
| #46 | 0.081 | 2.06 | 49,300 | 51,700 |
| #47 | 0.0785 | 1.99 | 46,300 | 48,600 |
| #48 | 0.076 | 1.93 | 43,400 | 45,500 |
| #49 | 0.073 | 1.85 | 40,100 | 42,000 |
| #50 | 0.070 | 1.78 | 36,800 | 38,600 |
| #51 | 0.067 | 1.70 | 33,700 | 35,400 |
| #52 | 0.0635 | 1.61 | 30,300 | 31,800 |
| #53 | 0.0595 | 1.51 | 26,600 | 27,900 |
| #54 | 0.055 | 1.40 | 22,700 | 23,800 |
| #55 | 0.052 | 1.32 | 20,300 | 21,300 |
| #56 | 0.0465 | 1.18 | 16,300 | 17,000 |
| #57 | 0.043 | 1.09 | 13,900 | 14,600 |
| #58 | 0.042 | 1.07 | 13,300 | 13,900 |
| #59 | 0.041 | 1.04 | 12,600 | 13,300 |
| #60 | 0.040 | 1.02 | 12,000 | 12,600 |
| #61 | 0.039 | 0.99 | 11,400 | 12,000 |
| #62 | 0.038 | 0.97 | 10,900 | 11,400 |
| #63 | 0.037 | 0.94 | 10,300 | 10,800 |
| #64 | 0.036 | 0.91 | 9,740 | 10,200 |
| #65 | 0.035 | 0.89 | 9,210 | 9,660 |
| #66 | 0.033 | 0.84 | 8,190 | 8,590 |
| #67 | 0.032 | 0.81 | 7,700 | 8,070 |
| #68 | 0.031 | 0.79 | 7,220 | 7,580 |
| #69 | 0.0292 | 0.74 | 6,410 | 6,720 |
| #70 | 0.028 | 0.71 | 5,890 | 6,180 |
| #71 | 0.026 | 0.66 | 5,080 | 5,330 |
| #72 | 0.025 | 0.64 | 4,700 | 4,930 |
| #73 | 0.024 | 0.61 | 4,330 | 4,540 |
| #74 | 0.0225 | 0.57 | 3,810 | 3,990 |
| #75 | 0.021 | 0.53 | 3,320 | 3,480 |
| #76 | 0.020 | 0.51 | 3,010 | 3,150 |
| #77 | 0.018 | 0.46 | 2,440 | 2,550 |
| #78 | 0.016 | 0.41 | 1,920 | 2,020 |
| #79 | 0.0145 | 0.37 | 1,580 | 1,660 |
| #80 | 0.0135 | 0.34 | 1,370 | 1,440 |
Metric Orifice Size Chart (mm)
Many fireplace and grill orifices are sized in millimeters, such as Empire's 1.45 mm and 1.55 mm fireplace orifices or Broilmaster's 1.05 to 2.37 mm grill orifices. Same basis as the tables above.
| Orifice (mm) | Diameter (in.) | Natural gas BTU/hr at 3.5 in. w.c. | Propane BTU/hr at 10.0 in. w.c. | Propane BTU/hr at 11.0 in. w.c. |
|---|---|---|---|---|
| 0.80 | 0.0315 | 2,810 | 7,460 | 7,820 |
| 0.85 | 0.0335 | 3,170 | 8,420 | 8,830 |
| 0.90 | 0.0354 | 3,550 | 9,440 | 9,900 |
| 0.95 | 0.0374 | 3,960 | 10,500 | 11,000 |
| 1.00 | 0.0394 | 4,390 | 11,700 | 12,200 |
| 1.05 | 0.0413 | 4,840 | 12,800 | 13,500 |
| 1.10 | 0.0433 | 5,310 | 14,100 | 14,800 |
| 1.15 | 0.0453 | 5,800 | 15,400 | 16,200 |
| 1.20 | 0.0472 | 6,320 | 16,800 | 17,600 |
| 1.25 | 0.0492 | 6,860 | 18,200 | 19,100 |
| 1.30 | 0.0512 | 7,420 | 19,700 | 20,700 |
| 1.35 | 0.0531 | 8,000 | 21,200 | 22,300 |
| 1.40 | 0.0551 | 8,600 | 22,800 | 24,000 |
| 1.45 | 0.0571 | 9,230 | 24,500 | 25,700 |
| 1.50 | 0.0591 | 9,870 | 26,200 | 27,500 |
| 1.55 | 0.0610 | 10,500 | 28,000 | 29,400 |
| 1.60 | 0.0630 | 11,200 | 29,800 | 31,300 |
| 1.65 | 0.0650 | 11,900 | 31,700 | 33,300 |
| 1.70 | 0.0669 | 12,700 | 33,700 | 35,300 |
| 1.75 | 0.0689 | 13,400 | 35,700 | 37,400 |
| 1.80 | 0.0709 | 14,200 | 37,800 | 39,600 |
| 1.85 | 0.0728 | 15,000 | 39,900 | 41,800 |
| 1.90 | 0.0748 | 15,800 | 42,100 | 44,100 |
| 1.95 | 0.0768 | 16,700 | 44,300 | 46,500 |
| 2.00 | 0.0787 | 17,600 | 46,600 | 48,900 |
| 2.05 | 0.0807 | 18,400 | 49,000 | 51,400 |
| 2.10 | 0.0827 | 19,400 | 51,400 | 53,900 |
| 2.15 | 0.0846 | 20,300 | 53,900 | 56,500 |
| 2.20 | 0.0866 | 21,200 | 56,400 | 59,100 |
| 2.25 | 0.0886 | 22,200 | 59,000 | 61,900 |
| 2.30 | 0.0906 | 23,200 | 61,600 | 64,600 |
| 2.35 | 0.0925 | 24,200 | 64,300 | 67,500 |
| 2.40 | 0.0945 | 25,300 | 67,100 | 70,400 |
| 2.45 | 0.0965 | 26,300 | 69,900 | 73,400 |
| 2.50 | 0.0984 | 27,400 | 72,800 | 76,400 |
| 2.55 | 0.1004 | 28,500 | 75,800 | 79,500 |
| 2.60 | 0.1024 | 29,700 | 78,800 | 82,600 |
| 2.65 | 0.1043 | 30,800 | 81,800 | 85,800 |
| 2.70 | 0.1063 | 32,000 | 84,900 | 89,100 |
| 2.75 | 0.1083 | 33,200 | 88,100 | 92,400 |
| 2.80 | 0.1102 | 34,400 | 91,400 | 95,800 |
| 2.85 | 0.1122 | 35,600 | 94,600 | 99,300 |
| 2.90 | 0.1142 | 36,900 | 98,000 | 102,800 |
| 2.95 | 0.1161 | 38,200 | 101,400 | 106,400 |
| 3.00 | 0.1181 | 39,500 | 104,900 | 110,000 |
| 3.05 | 0.1201 | 40,800 | 108,400 | 113,700 |
| 3.10 | 0.1220 | 42,200 | 112,000 | 117,400 |
| 3.15 | 0.1240 | 43,500 | 115,600 | 121,300 |
| 3.20 | 0.1260 | 44,900 | 119,300 | 125,100 |
| 3.25 | 0.1280 | 46,400 | 123,100 | 129,100 |
| 3.30 | 0.1299 | 47,800 | 126,900 | 133,100 |
| 3.35 | 0.1319 | 49,300 | 130,800 | 137,100 |
| 3.40 | 0.1339 | 50,700 | 134,700 | 141,300 |
| 3.45 | 0.1358 | 52,200 | 138,700 | 145,500 |
| 3.50 | 0.1378 | 53,800 | 142,700 | 149,700 |
Heating Values Used: 1,000 vs 2,500 BTU per Cubic Foot
The charts assume 1,000 BTU per cubic foot for natural gas and 2,500 for propane, the round numbers most charts and appliance manuals work from. Real gas varies a little:
- Natural gas: gas delivered in the US averaged about 1,037 BTU per cubic foot in 2025, according to the US Energy Information Administration, so real input on typical pipeline gas can run up to about 4% above these figures. Your gas utility can tell you the heating value at your address.
- Propane: propane vapor carries roughly 2,500 BTU per cubic foot at 60 °F. RegO's LP-gas manual lists 2,488 for commercial propane and the NFPA 58 property table lists 2,516, so the 2,500 basis here is within about 1% of both.
- Why propane orifices are so much smaller: propane carries 2.5 times the energy per cubic foot and runs at about three times the pressure. For the same input, a propane orifice at 10 in. w.c. needs only about 38% of the hole area of a natural gas orifice at 3.5 in. w.c., or roughly 0.6 times the diameter. A 30,000 BTU/hr burner works out to a #37 or #38 orifice on natural gas and a #52 or #53 on propane.
- Why the wrong orifice is dangerous: a natural gas orifice run on propane at 10 in. w.c. would pass about 2.7 times the heat it was sized for, and a propane orifice on natural gas only about 38%.
To check what an appliance is really burning, the installer can clock the gas meter with every other gas appliance off: 3,600 divided by the seconds it takes to use one cubic foot gives cubic feet per hour, and that times the heating value gives BTU per hour.
High-Altitude Orifice Sizing and Derating
These charts are for sea level. In the US, gas appliances installed above 2,000 ft are derated: input is reduced 4% for each 1,000 ft above sea level, following the American Gas Association guideline that appliance manuals cite. In Canada, the standard rating covers 0 to 4,500 ft, and above 4,500 ft the certified high-altitude rating is reduced 4% for each additional 1,000 ft (CSA B149.1).
- Example: a fireplace rated 30,000 BTU/hr at sea level, installed at 5,000 ft, should run at about 30,000 × (1 − 5 × 0.04) = 24,000 BTU/hr.
- The derate is done with a smaller orifice. Makers supply high-altitude orifices; Lennox's changeover and high-altitude kits for its UHCM unit heaters, for example, step from a #41 orifice up to 4,000 ft to a #44 at 4,001 to 8,000 ft and a #47 at 8,001 to 10,000 ft. Keep the manifold pressure at the rating plate value.
- Check the gas, too. Some utilities at high elevation deliver gas with a lower heating value, which lowers input on its own. Carrier's furnace instructions, for example, size orifices from the heating value the local utility reports at the installed altitude. Ask your utility, then follow the appliance maker's high-altitude instructions.
When you enter an altitude above 2,000 ft, the calculator applies the 4% rule to your target input and sizes the orifice from sea-level values. That simple method leans toward a smaller orifice; the maker's high-altitude orifice size always overrides it.
Safety: Who Should Change a Gas Orifice
Orifice changes and gas conversions are work for a licensed gas installer or the dealer's service technician, not a homeowner project. The makers' conversion instructions say so: Empire's kits are to be installed by an Empire distributor or other qualified agency, and Kozy Heat warns that if its instructions are not followed exactly, a fire, explosion or carbon monoxide may result, causing property damage, personal injury or loss of life.
- Convert only with the maker's kit for your exact model. A conversion is more than an orifice. Empire's fireplace kits include front and rear burner orifices, a SIT valve conversion kit and a conversion label, and the steps include resetting the air shutters; Kozy Heat's kits include burner orifices, a pilot injector, a stepper motor and labels. Find your model number first, or check the rating plate.
- Do not drill, ream or substitute an orifice from a chart to change an appliance's input. Use the size the maker specifies for your model, gas and altitude.
- After the work, the installer should: check every connection for leaks with soapy water, set inlet and manifold pressure with a manometer to the rating plate, verify the input (clock the meter, or check manifold pressure where there is no meter), check the main burner and pilot flames, run the safety shutdown test (on Empire's IPI fireplaces, pilot gas flow should stop within 30 seconds of turning the unit off) and fix the gas conversion label to the appliance.
- If you smell gas, do not try to light any appliance. Leave the building and call your gas supplier or 911 from outside. More in our gas fireplace safety tips.
Orifices and Conversion Kits We Carry
Match the part number in your manual or on your model's parts list before ordering. A kit or orifice made for one model is not a universal part, even when the stamped size matches.
Find parts for your exact appliance: gas valves and conversion kits · Empire fireplace parts · HHT (Heat N Glo, Heatilator, Quadra-Fire) parts · Broilmaster grill parts.
Gas Orifice FAQ
What size orifice do I need for my BTU rating?
Divide the rated input by the number of orifices, then find the drill size closest to that figure without going over, in the column for your gas and pressure. For 30,000 BTU/hr on one orifice, that is a #38 (about 29,200 BTU/hr) on natural gas at 3.5 in. w.c., or a #53 (about 26,600) to #52 (about 30,300) on propane at 10 in. w.c. On a fireplace, the orifice the maker lists for your model always wins.
What is the difference between a natural gas and a propane orifice?
The hole size. For the same input, a propane orifice is roughly 0.6 times the diameter of the natural gas one, because propane carries more energy per cubic foot and runs at higher pressure. The fittings can look alike, so read the stamped size.
Can I convert my gas fireplace by changing the orifice?
No. A conversion also changes the valve's regulated pressure (about 3.5 in. w.c. on natural gas vs 10.0 on propane for Empire's fireplaces, done with a SIT valve conversion kit), often the pilot injector, and sometimes the air shutter setting. Use the maker's kit for your model and have a qualified installer do the work.
How do I adjust orifice size for high altitude?
In the US, reduce the sea-level input 4% for every 1,000 ft above sea level once you are above 2,000 ft, and use the smaller orifice the maker specifies for that elevation. At 6,000 ft that is a 24% reduction. Also ask your utility for the heating value of your gas, because lower-BTU gas at altitude already reduces input.
Are orifice sizes the same as drill sizes?
Usually. Most orifices are stamped with a number drill size (#1 to #80) or a metric diameter in millimeters, and the hole matches that drill. The drill diameters in these charts follow the ASME B94.11M twist drill standard. Pilot injectors are the exception; many carry the maker's own code.
How These Numbers Were Calculated
Every value comes from the standard orifice flow equation: Q = 1658.5 × Cd × A × √(P ÷ G), where Q is cubic feet per hour, A is the hole area in square inches (π × d² ÷ 4), P is the manifold pressure in inches of water column, G is the gas specific gravity (air = 1) and Cd is the discharge coefficient. BTU per hour = Q × heating value. We used Cd 0.90 and specific gravity 0.60 for natural gas, values that reproduce the National Fuel Gas Code (NFPA 54) natural gas orifice table, and specific gravity 1.52 for propane.
We checked the results three ways. Against the NFPA 54 natural gas values at 3.5 in. w.c., 62 of 63 drill sizes agree within 5% and 56 within 1%; the one miss is a misprinted row in the reprint we used. Against the NFPA 54 propane table at 11 in. w.c., reprinted in RegO's LP-Gas Serviceman's Manual, our propane values run 2% to 3% lower on the same heating value, on every row but one misprinted one. Against seven maker-rated fireplace inputs from Empire and Kozy Heat conversion instructions, the computed input lands within about 4% of the rating every time (the widest gap is 4.1%, Empire's DVCT36 on natural gas).
Related Guides
Gas orifice size calculator
Find the drill size for a BTU rating, or the BTU rating of an orifice you have, for natural gas or propane. Results are estimates; the rating plate and the maker's conversion kit decide.
Estimates only. These figures come from the standard orifice equation (discharge coefficient 0.90) and are accurate to roughly plus or minus 5%. Real orifices, burners and gas vary. Your appliance's rating plate and the maker's conversion kit always take priority, and orifice changes or gas conversions must be done by a qualified gas installer.